Manual (LOCAL) Operation
Recall Positions
Recall from non-volatile memory the state of the positions of all
switch ID’s configured to the matrix, saved as 1 through 30, and
set the positions of those switches.
Clear Positions
Cause all switches configured to the matrix to assume their
default position. For most switches this is position 0 (open
positions). Note that all Dow-Key switches have “open” defined,
but not all switch types have an actual open position, such as a
transfer switch. In this case, “open” means “close on its default
position 1”.
Cycle Positions
Step all switches configured to the matrix through all of their
positions. NOTE: the Cycle Position function is intended for use
at the Dow-Key factory during the assembly process. In fact,
the Cycle Position function will generate errors when
commanding a Transfer switch to switch from position 0 to
position 1, which may be ignored. For this reason, the Operator
is discouraged from exercising Cycle Positions.