Dow-Key Microwave MS-1U18S-6-ENET Instrukcja Operatora

Przeglądaj online lub pobierz Instrukcja Operatora dla Switche sieciowe Dow-Key Microwave MS-1U18S-6-ENET. Dow-Key Microwave MS-1U18S-6-ENET Operator`s manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - MS, MP, CB Matrix Series

i “There Is No Substitute for Experience” DOW-KEY MICROWAVE MS, MP, CB Matrix Series MS-2U18SFRL-4/X-GPIB CAN BUS RF SWITCH MATRIX Operator’s Manua

Strona 2

4 General Information 1.4 CB Matrices CB-Series stands for Crossbar. It is a matrix with several inputs connecting to several outputs. Only one input

Strona 3 - WARRANTY

5 General Information 1.5 Technical Specifications Refer to appendix A

Strona 4 - Manual Revision History

6 General Information 1.6 Safety Precaution Safety precautions should be observed before using this product and any associated instrumentation. This

Strona 5 - Table of Contents

7 2 System Layout 2.1 Front Panel Layout 2 Note: The matrices shown below are with the LCD on the front panel and rear mounted switches. Matrices wi

Strona 6

8 System Layout 2.2 Rear Panel Layout for 2U models Figure 2-2 shows the general layout of the rear panel of a variety of 2U models. All models have

Strona 7 - 1 General Information

9 System Layout 2.3 Rear Panel Layout for 3U models Figure 2-3 shows the general layout of the rear panel of a variety of 3U models. All models have

Strona 8 - 1.2 MS Matrices

10 System Layout 3U MS series (with external switches) 3U MS series (with internal switches) or MP series or CB series 3U

Strona 9 - 1.3 MP Matrices

11 System Layout 2.4 Rear Panel Layout for 4U models Figure 2-4 shows the general layout of the rear panel of a variety of 4U models. All models hav

Strona 10 - 1.4 CB Matrices

12 System Layout 4U MS series (with external switches) 4U MS series (with internal switches) or MP series or CB series 4U MS seri

Strona 11 - 1.5 Technical Specifications

13 System Layout 2.5 Top View Layout Figure 2-5 shows the top view layout of all models. Note: The dimension indicated on the drawing is for 3

Strona 12 - 1.9 Repacking for shipment

ii Copyright © Dow-Key Microwave Corporation 2010, all rights reserved. Information in this publication supersedes that in all previously published m

Strona 13 - 2 System Layout

14 System Layout 2.6 RF configuration Refer to appendix B.

Strona 14

15 3 Connections 3.1 Power Connection 3.1.1 Line Voltage The matrix operates from a line voltage in the range of 110V to 240V at a frequency of 50 o

Strona 15

16 Connections Insert small bladed screwdriver to release the fuse. Figure 3-1, Power Entry Module Line Voltage Fuse Rating Manufacturer Manufactu

Strona 16

17 Connections 3.3 RS232 Connection The switch matrix may be operated over this connection (See Section 6 for a description of the commands). The RS

Strona 17

18 Connections 3.4 CAN Bus Connection This connection allows the internal matrix controller to be easily interfaced to another Dow-Key Microwave Swit

Strona 18

19 Connections 3.5 GPIB Control Connection On the rear panel of the matrix is a GPIB (IEEE-488) control port which gets connected to the GPIB port o

Strona 19 - 2.5 Top View Layout

20 Connections 3.5.2 Interface Signals The GPIB (IEEE-488) interface system consists of 16 signal lines and 8 ground lines. The 16 signal lines are

Strona 20 - 2.6 RF configuration

21 Connections 3.5.4 Handshake Lines The three handshake lines (NRFD, NDAC, DAV) control the transfer of message bytes among the devices and form th

Strona 21 - 3 Connections

22 Connections The REN (Remote Enable) signal is asserted only by the System Controller. Its assertion does not place devices into remote control m

Strona 22 - 3.2 Ground Connection

23 4 Configuring the Matrix for Operation 4.1 Matrix Configuration The ‘brain’ inside Dow-Key Matrices, referred to as the “Matrix Controller”, has b

Strona 23 - 3.3 RS232 Connection

iii WARRANTY Dow-Key Microwave Corporation warrants this product to be free from defects in material and workmanship for a period of 1 year from date

Strona 24 - 3.4 CAN Bus Connection

24 Configuring the Matrix 4.3 Adding and Deleting Switches The following rules apply when adding a switch to the Matrix Configuration (the desired I

Strona 25 - 3.5 GPIB Control Connection

25 Configuring the Matrix Example procedure: Before adding it to the Configuration you need to find the switch’s ID. To do this select Main Menu>

Strona 26

26 5 Manual (LOCAL) Operation 5.1 The Touch Screen Interface Power On: Position the rocker switch on the rear panel of the Matrix to the ON positi

Strona 27

27 Manual (LOCAL) Operation The figure above shows the matrix LCD touch screen (sometimes referred to as the “User Interface”, or “UI”) a

Strona 28 - 3.6 USB Port

28 Manual (LOCAL) Operation 5.2 Main Menu 5.2.1 Switching Operations Switch Operations Menu Set Switch Positions View the currently set position a

Strona 29 - 4.1 Matrix Configuration

29 Manual (LOCAL) Operation Recall Positions Recall from non-volatile memory the state of the positions of all switch ID’s configured to the matrix,

Strona 30

30 Manual (LOCAL) Operation 5.2.2 Error Operations View the contents of the Error Log (see Section 7.5.1). Each entry is displayed with the oldest b

Strona 31

31 Manual (LOCAL) Operation 5.2.3 System Settings System Settings Menu ! Important Note: The matrix controller is designed to offer the maximum expa

Strona 32 - 5 Manual (LOCAL) Operation

32 Manual (LOCAL) Operation 4. NOTE: this operation “puts the matrix’s switches to sleep” thereby rendering the matrix inoperable during the proces

Strona 33

33 Manual (LOCAL) Operation 5.2.4 Ethernet Options Ethernet Menu Not applicable to GPIB (IEEE-488) models. This button is not operational. 5.2.5

Strona 34 - 5.2 Main Menu

iv Manual Revision History The revision history shown below lists all revisions and addendums created for this manual. The revision level increases n

Strona 35

34 6 IEEE 488.2 Register model 6.1 Introduction to IEEE 488.2 The topics discussed in sections 4.2 to 4.3 are for the most part transparent to

Strona 36

35 IEEE 488.2 Register Model 6.5 The Status Byte Register The Status Byte register reports conditions from the other registers. Data in the instr

Strona 37

36 IEEE 488.2 Register Model 6.6 The Standard Event Register The Standard Event Register reports different types of events that may occur in the in

Strona 38

37 IEEE 488.2 Register Model 6.7 IEEE 488.2 Common Commands This matrix implements common commands that the IEEE-488.2 standard defines. The foll

Strona 39

38 7 Remote Operation 7.1 Introduction to SCPI SCPI is a command structure that is based on the IEEE-488.2 specification which Dow-key has adapte

Strona 40 - IEEE 488.2 Register model

39 Remote Operation 7.3 Command Separators and conventions • A colon (:) is used to separate a command keyword from a lower level keyword. • A bl

Strona 41

40 Remote Operation 7.4 Common Commands The following contains the IEEE 488.2 common commands of SCPI that the GPIB controller is compatible with. T

Strona 42

41 Remote Operation 7.4.3 *ESE? Syntax *ESE? Description This query allows the user to determine the current contents of Standard Event Statu

Strona 43

42 Remote Operation 7.4.5 *IDN? Syntax *IDN? Result A string is returned which consists of the following parts: Model Model Matrix model num

Strona 44 - 7 Remote Operation

43 Remote Operation 7.4.7 *OPC? Syntax *OPC? Description This query returns an ASCII character “1” when all pending operations have been finished.

Strona 45

vi Table of Contents 1 General Information ... 11

Strona 46

44 Remote Operation 7.4.8 *RST Syntax *RST Description This command performs a device reset. This will set the instrument so that all switches are

Strona 47

45 Remote Operation 7.4.10 *SRE Syntax *SRE <enable_value> Parameters Enable_value Value that corresponds to the binary-weighted sum of the

Strona 48

46 Remote Operation 7.5 System Commands The following contains the SCPI system commands that the GPIB, RS-232 and USB control is compatible with.

Strona 49

47 Remote Operation Example “SYST:ERR?” Result was “1, INVALID CHARACTER”, check for more errors. Description: This error is no longer supporte

Strona 50

48 Remote Operation SYST:ERR?” Result was “10, SWITCH DID NOT RESPOND,x”, check for more errors. Description: Switch x did not respond to a position

Strona 51

49 Remote Operation SYST:ERR?” Result was “30, COMMAND UNRECOGNIZED”, check for more errors. Description: This error code is generated when the comm

Strona 52

50 Remote Operation 7.5.2 SYST:SERIALNUMBER? Syntax SYSTem:SERIALNUMBER? Description Returns the matrix serial number. Result n Possible error co

Strona 53

51 Remote Operation 7.5.3 SYST:STATUS? Syntax SYSTem:STATUS? Description This command will return all Switch positions, Local/Remote mode, Power s

Strona 54

52 Remote Operation 7.5.4 SYST:SCREENSAVER? Syntax SYSTem:SCREENSAVER? Description This command will return the screen saver time settings n (n is

Strona 55

53 Remote Operation 7.5.6 SYST:GPIBADDRESS? Syntax SYSTem:GPIBADDRESS? Description This command will return the matrix’s GPIB address. Possible va

Strona 56

vi 6.2 Condition Register ... 346.3 Event Register ...

Strona 57

54 Remote Operation 7.6 Switch [Module] Command Set The following contains the switch [module] commands of SCPI that the GPIB / RS 232 / USB con

Strona 58

55 Remote Operation 7.6.2 Setting switch x to position n x = switch [module] address. n = position to set and must be within the switches paramete

Strona 59

56 Remote Operation 7.6.3 Requesting Switch x current position x = switch address. Examples: • ROUTE:SWITCHx? • ROUT:SWITx? • :SWITx? Result: Ret

Strona 60

57 Remote Operation This page intentionally left blank

Strona 61

58 GPIB, RS232 and USB Command description for standard matrices Command Syntax Response Action 1 *IDN? MS-2U18S-3/10-GPIB Returns string in ’Mod

Strona 62

59 Remote Operation Note: 1. Commands are NOT case sensitive. 2. For GPIB communication no ASCII termination is required, but the End Or Identify

Strona 63 - Remote Operation

60 Appendix A Technical Specifications Model: MS-2U18SFRL-4/X-GPIB Configuration: 4 Transfer switches mounted on the front panel RF Connectors

Strona 64

61 Appendix A Front View:

Strona 65

62 Appendix B RF Configuration Model: MS-2U18SFRL-4/X-GPIB Four independent transfer switches (Dow-Key part number: 411L-420832N-ROHS) mounted on t

Strona 66 - Appendix A

1 1 General Information 1.1 Introduction The Dow-Key Microwave MS, MP, CB Switch Matrix series are electromechanical RF matrices. They come equipped

Strona 67

2 General Information 1.2 MS Matrices MS-Series stands for Multiple Switches. It is a matrix where a number of independent switches are populated on

Strona 68 - Appendix B

3 General Information 1.3 MP Matrices MP-Series stands for Multiplexer. It is a matrix with one input connecting to many outputs (only one at the ti

Komentarze do niniejszej Instrukcji

Brak uwag