Dow-Key Microwave MS-1U18S-4 Instrukcja Operatora Strona 30

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 65
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 29
24
Manual (LOCAL) Operation
Recall Positions
Recall from non-volatile memory the state of the positions of all
switch ID’s configured to the matrix, saved as 1 through 30, and
set the positions of those switches.
Clear Positions
Cause all switches configured to the matrix to assume their
default position. For most switches this is position 0 (open
positions). Note that all Dow-Key switches have “open” defined
but not all switch types have an actual open position, such as a
transfer switch. In this case “open” means “close on its default
position 1”.
Cycle Positions
Step all switches configured to the matrix through all of their
positions. NOTE: the Cycle Position function is intended for use
at the Dow-Key factory during the assembly process. In fact,
the Cycle Position function will generate errors when
commanding a Transfer switch to switch from position 0 to
position 1, which may be ignored. For this reason, the Operator
is discouraged from exercising Cycle Positions.
Przeglądanie stron 29
1 2 ... 25 26 27 28 29 30 31 32 33 34 35 ... 64 65

Komentarze do niniejszej Instrukcji

Brak uwag